Accurate arterial path length estimation for pulse wave velocity calculation in growing children and adolescents

dc.contributor.authorWitbooi, Lee-Roy C.en_ZA
dc.contributor.authorPage, Benen_Za
dc.contributor.authorPitcher, Richard D.en_ZA
dc.contributor.authorInnes, Steveen_ZA
dc.date.accessioned2023-04-20T07:35:13Zen_ZA
dc.date.available2023-04-20T07:35:13Zen_ZA
dc.date.issued2021-05en_ZA
dc.descriptionCITATION: Witbooi LRC, Page B, Pitcher RD and Innes S. Accurate arterial path length estimation for pulse wave velocity calculation in growing children and adolescents. Gates Open Res 2021, 5:87. doi.10.12688/gatesopenres.13178.1)en_ZA
dc.descriptionThe original publication is available at: gatesopenresearch.orgen_ZA
dc.description.abstractBackground: Most adult cardiovascular disease begins in childhood. Given the burgeoning obesity pandemic in children worldwide, there is a need for precise and scalable surveillance methods to detect subclinical cardiovascular disease in children and adolescents. Early detection allows early intervention and intensified primary prevention strategies in affected individuals. Carotid-femoral pulse wave velocity (PWV) directly measures arterial wall stiffness, an early feature of atherosclerosis. Calculation of PWV in growing children requires an accurate estimation of the true distance travelled by the aorto-femoral pressure wave, using surface anatomy landmarks. However, a variety of methods are used to estimate this distance, and these have not previously been investigated in growing children and adolescents. We sought to investigate this by comparing true arterial path length measured on computerized tomography (CT) scans, with a variety of estimations based on surface anatomy landmarks. Methods: Arterial path lengths were measured using multi-planar reformation (MPR) imaging software. These measurements were then compared with the surface anatomy measurements obtained using the same MPR imaging software. The fidelity of a variety of arterial path length estimation methods was tested. Results: The surface anatomy distance between the suprasternal notch and the angle of the mandible (PWV recording site in the neck), should be adjusted using the formula y=4.791+(1.0534*x). This value subtracted from the unadjusted distance from the suprasternal notch to the umbilicus, through the mid-inguinal crease to the femoral PWV recording site, provides the simplest reliable approximation of true intraluminal distance travelled. Conclusions: There is high correlation between the surface anatomy distances and the arterial path lengths they represent; however, these are not equal. Most surface anatomy measurements require adjustment using the formulae that we have provided, to accurately estimate the true distance travelled by the pulse wave.en_ZA
dc.description.versionPublisher’s versionen_ZA
dc.format.extent14 pagesen_ZA
dc.identifier.citationWitbooi LRC, Page B, Pitcher RD and Innes S. Accurate arterial path length estimation for pulse wave velocity calculation in growing children and adolescents. Gates Open Res 2021, 5:87. doi.10.12688/gatesopenres.13178.1)en_ZA
dc.identifier.issn2572-4754 (online)en_ZA
dc.identifier.otherdoi.10.12688/gatesopenres.13178.1)en_ZA
dc.identifier.urihttp://hdl.handle.net/10019.1/126800en_ZA
dc.language.isoen_ZAen_ZA
dc.publisherGates Open Researchen_ZA
dc.rights.holderAuthors retain copyrighten_ZA
dc.subjectCardiovascular system -- Diseasesen_ZA
dc.subjectArterial path lengthen_ZA
dc.subjectCardiovascular system -- Diseases.en_ZA
dc.subjectMPRen_ZA
dc.subjectMulti planar reformationen_ZA
dc.subjectObesity -- Complicationsen_ZA
dc.titleAccurate arterial path length estimation for pulse wave velocity calculation in growing children and adolescentsen_ZA
dc.typeArticleen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
witbooi_accurate_2021.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:
download article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: