The conceptual design and development of novel low cost sensors for measuring the relative light emission in the pre-millisecond stages of detonating explosive charges

dc.contributor.advisorPerold, W. J.en_ZA
dc.contributor.advisorMostert, F. J.en_ZA
dc.contributor.authorOlivier, Mariusen_ZA
dc.contributor.otherStellenbosch University. Faculty of Engineering. Dept. of Electrical and Electronic Engineering.en_ZA
dc.date.accessioned2012-11-28T09:01:02Zen_ZA
dc.date.accessioned2012-12-12T08:08:51Z
dc.date.available2012-11-28T09:01:02Zen_ZA
dc.date.available2012-12-12T08:08:51Z
dc.date.issued2012-12en_ZA
dc.descriptionThesis (MScEng)--Stellenbosch University, 2012.en_ZA
dc.description.abstractENGLISH ABSTRACT: During the course of the CSIR’s research into the characterisation of explosive sources to devise methods of active intervention against threats, the need has arisen to research a particular means of early identification of the threat, which is the intense light flash during the threat detonation. For this purpose, a low cost rugged fast optical sensor was sought, since the application thereof would imply possible destruction, especially if integrated into an active intervention system later on. Given the average time of about 1ms available for intervention, it is clear that the active intervention system needs to operate within that period, hence the interest in the characteristic light emission of detonations in the pre-millisecond time frame. It was thought that by characterising this emitted light in terms of wavelength (temperature) and amplitude (and maybe other unique phenomena), the size of the threat could be determined and logic decisions derived therefrom. Needless to say, the environment in which the detonation light emission sensor is to operate, is extremely hostile in terms of shock, dust, flying debris, fast rise time of the explosive event, and Electro-magnetic Interference ( EMI) caused by the detonation itself. It must be noted that the light sensor research was driven by the outcome of research tests performed in aid of the development of an active intervention system. During this research the possibility of using commercially available low cost optical detectors at room temperature in combination with cost effective narrow band pass op- tical filters for the relative measurement of the light emission at discrete wavelengths during explosive detonation events were investigated. In 2006, not much applicable lit- erature could be found on this subject, hence the educated “shot-in-the-dark” approach then, which, by a systematic approach of explosive tests and continuous evaluation up to 2011, led to a surprisingly simple and robust low cost optical sensor. The research commenced with a range of optical detector elements selected for their responsivity and bandwidth in the optical spectrum of interest; the optical filtering by means of the recording of the emitted light signal during scaled down explosive tests at the Blast Impact Survivability Research Unit (BISRU) at the University of Cape Town. These tests were followed by full-scale tests at DBEL, and confirmed the findings at BISRU that the light emissions at the longer wavelengths (>2 m) manifest themselves too late for use within the intervention time frame. It was therefore decided to concentrate on the ultra-violet (UV) to near infra-red (NIR) spectrum of the emitted light for further full scale tests, since these discrete spectra showed the most promise for characterisa- tion of the emitted light. During this period a robust sensor housing with detector and filter mounts was designed for protection against blast shock and EMI. During the following years, certain types of optical detectors that were used during previous tests were eliminated according to results obtained, and more discrete narrow band pass filters added in the visible to NIR spectrum. A dedicated fast instrumen- tation amplifier (bandwidth > 1MHz and selectable gain up to 40dB) was developed to amplify weak signals (mainly caused by the heavy load in the detector circuit to improve rise times). However, the emission of light per wavelength in this region was measured to be relatively strong, and actually not as fast as was anticipated. This meant that the load resistor value of the detector element could be increased without affecting the signal negatively (bandwidth sufficient), thus adding to the amplitude of the signal to such a point that amplification in a 10m to 30 meter stand-off scenario was no longer needed. This culminated in an unamplified universal detector element being used with various narrow band pass filters up to 1 m, integrated as a very robust analog sensor at a discrete wavelength, and facilitating the direct comparison of light amplitude/relative intensity of the detonation at discrete spectral points. The sensor was employed in the field at various full scale explosive tests at DBEL, which led to the capture of a vast amount of light emitted data for different types of explosives, at various distances from the detonation, and of varying mass. Analysis of this data showed that the broadband light intensity of the emitted light scales to the explosive mass1/3 (as published by FJ Mostert and M Olivier in the Journal for Applied Physics, October 2011). Further analysis also confirmed the attenuation of the emitted light intensity by the square of the distance. Besides the aforesaid, various other key inputs to a possible active intervention algorithm have been identified. These findings are inputs to the determination of i.a. the detonation threat size, a vital component in the active intervention algorithm. The results of these experiments confirmed that the final low cost analog sensor can measure relative light emission at discrete wavelengths from detonation of explosives in the very early stages of development, and that the sensor has many other applications in the detonics research fields as well.en_ZA
dc.description.abstractAFRIKAANSE OPSOMMING: Gedurende die WNNR se navorsing om detonerende bronne te karakteriseer ten einde aktiewe teenmaatreëls daar te stel, het die behoefte na vore gekom om die intense ligflits van ’n detonasie te ondersoek en te karakteriseer. Vir hierdie doel is ’n lae koste ligsensor benodig, synde die uiteindelike aanwending van hierdie ligsensor die vernietiging daarvan sou beteken, aldus die lae koste vereiste. Gegewe die kort tydsduur van die detonasie (’n paar millisekondes), is dit duidelik dat die ligflits karakerisering voor 1ms moet geskied, en daarom moet die ligsensor ook baie vinnig reageer om insette te lewer tot ’n aktiewe teenmaatreëlstelsel. Daar moet op gelet word dat die ligsensor se ontwikkeling uitkomsgedrewe was deur die navorsingstoetse om ’n aktiewe teenmaatreëlstelsel daar te stel. Een van die insette tot so ’n aktiewe teenmaatreëlstelsel is die grootte van die bedreiging: deur die ligflits te karakteriseer met die lae koste ligsensors t.o.v. golflengte, ligamplitude en moontlik ander verskynsels, kan bv. die massa inset verkry word wat nodig is vir die teenmaatreël algoritme. Die omgewing waarin die ligsensor moet funksioneer is baie onvriendelik i.t.v. skok, stof, vlieënde partikels en elektromagnetiese steurings, en sou daarteen beskerm moes word. Gedurende die navoring om so ’n ligsensor te ontwikkel (samelopend met die teen- maatreël navorsing), is kommersiële kamertemperatuur detektors oorweeg en aange- wend, in samewerking met nouband optiese filters. Die doel was om die ligopbrengs per golflengte te karakteriseer m.b.t. die plofstof massa, plofstof tipe en geometrie, en die afstand vanaf die detonasie. Bitter min literatuur oor die ligmeting van detonasies is aanvanklik gevind, aldus is ’n basislyn daargestel en deur sistematiese toetsing, ontleding en verbetering voortgegaan met die navorsing. Dit het gelei tot ’n verrassend eenvoudige en verharde lae koste ligsensor, wat deur meting sleutelinsette kon lewer tot die gesogte aktiewe teenmaatreël algoritme. Kommersiële detektors en nouband optiese filters is uitgesoek na aanleiding van hul prys en prestasie, en waar nodig, is versterking van die seine aangebring. Verskeie toetse met plofstof (op klein en groot skaal) is uitgevoer, waartydens ligmeting by spesifieke golflengtes opgeneem is. Analise van hierdie data het getoon dat die langer golflengtes (>2 m) se verskyning te laat is vir insluiting in die teenmaatreël algoritme, en is dus geleidelik (of sistematies) uitgeskakel. Die klem het geskuif na die detonasie liguitsetting in die UV tot naby infrarooi spektrum, wat nuwe detektors en filters tot gevolg gehad het (uitkoms gebasseerde navorsing). In die proses is ’n instrumentasie versterker ontwerp en gebou, vir buffering en versterking van seine hoër as 1 MHz met ’n selekteerbare aanwins van tot 40dB. Toetse met volskaalse ladings het egter getoon dat die liguitset besonder sterk is in die UV tot naby infrarooi spektrum, en ’n onversterkte ligsensor is aldus op die proef gestel. Hierdie proeflopie het getoon dat die onversterkte ligsensor besonder goed funksioneer op afstande tot en met 30m, en daar is op hierdie model voortgebou. Die verharde onversterkte ligsensor is aangewend in verskeie verdere volskaalse plofstof toetse, en het data gelewer t.o.v. detonasie liguitstraling by spesifieke golflengtes vir tipes plofstof, plofstof massas, plofstof geometrie en afstande vanaf die detonasie. Analise van hierdie data het getoon dat breëband liguitsetting se intensiteit skaal met die plofstof massa1=3 (gepubliseer as ’n artikel deur FJ Mostert en M Olivier in die Journal of Applied Physics’ - Oktober 2011). Verdere analise het verskeie sleutelinsette tot ’n aktiewe teenmaatreël algoritme geïdentifiseer. Die uitkoms van hierdie eksperimentele navorsing het getoon dat die lae koste lig- sensor relatiewe liguitsetting van ’n detonasie by gekose golflengtes vinnig kan meet in die baie vroeë stadia van die detonasie. Buiten dit, het die sensor verskeie ander nuttige aanwending in die detonasie navorsingsveld.af
dc.format.extent124 p. : ill.
dc.identifier.urihttp://hdl.handle.net/10019.1/71686
dc.language.isoen_ZA
dc.publisherStellenbosch : Stellenbosch Universityen_ZA
dc.rights.holderStellenbosch Universityen_ZA
dc.subjectDetonationen_ZA
dc.subjectLight emissionen_ZA
dc.subjectOptical detectorsen_ZA
dc.subjectDissertations -- Electronic engineeringen_ZA
dc.subjectTheses -- Electronic engineeringen_ZA
dc.subjectExplosions -- Light emissions -- Measurementen_ZA
dc.titleThe conceptual design and development of novel low cost sensors for measuring the relative light emission in the pre-millisecond stages of detonating explosive chargesen_ZA
dc.typeThesis
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
olivier_conceptual_2012.pdf
Size:
126.18 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.99 KB
Format:
Plain Text
Description: