Masters Degrees (Nuclear Medicine)
Permanent URI for this collection
Browse
Browsing Masters Degrees (Nuclear Medicine) by Subject "Dissertations -- Radiodiagnosis"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemExtended Cr-51 RBC combined with Tc-99m RBC for the detection and localisation of occult GIT bleeding(Stellenbosch : Stellenbosch University, 2014-04) Modebe, Emmanuel Obinna; Ellmann, Annare; Stellenbosch University. Faculty of Medicine and Health Sciences. Dept. of Medical Imaging and Clinical Oncology, Nuclear Medicine. Radiodiagnosis.ENGLISH ABSTRACT: Background Occult blood loss from the gastrointestinal tract (GIT), causing iron deficiency often with anaemia, can be diagnostically and therapeutically challenging. This is because the endoscopic and radiologic tests may be negative due to the slow, chronic and intermittent nature of the gastrointestinal bleeding, making timing key in detection and localisation of the bleed. These limitations can be approached using two different radioactive isotopes. Firstly, we tested the sensitivity of extending Cr-51 RBC for 21 days relative to 5 days to detect GIT bleeding and its use to optimise timing of a Tc-99m RBC study for GIT blood loss localisation. Finally, we tested if the information provided by the Tc-99m RBC study aided gastroenterologic intervention for anatomical localisation of a lesion. Method In this retrospective review, after obtaining institutional and ethics committee approval, records of patients referred for evaluation of possible GIT blood loss were reviewed. In each; daily appearance of radiochromium in stool was measured in the whole body counter. In those cases exceeding 50 ml/day, a technetium-99m (Tc-99m) localization study was performed. These studies were correlated with clinical findings. Results A total of 59 Cr-51 RBC studies were carried out in 36 females and 21 males (n = 57). In 32 (54%) the radiochromium results were positive with 75% of the bleeding incidences occurring after 5 days of stool collection. Of 17 cases in whom Tc-99m RBC imaging studies were performed, 14 (82%) were positive with specific anatomical sites successfully defined in twelve. In all patients with blood loss of >100 ml/24h, Tc-99m RBC were positive and localised. Ten of the 17 Tc-99m RBC studies were further investigated and half diagnosed with small-bowel angiodysplasia. Conclusion This sequential twin isotope method is practical in revealing otherwise silent intestinal haemorrhage. Although it has good patient acceptability and clinical as well as diagnostic utility in management, further studies are required to clearly establish a cut-off level of blood loss for performing imaging studies and the impact of the findings on the overall patient management.