Masters Degrees (Nuclear Medicine)
Permanent URI for this collection
Browse
Browsing Masters Degrees (Nuclear Medicine) by Subject "Dissertations -- Nuclear medicine"
Now showing 1 - 10 of 10
Results Per Page
Sort Options
- ItemThe added value of SPECT/CT in complicated osteomyelitis(Stellenbosch : Stellenbosch University, 2013-12) Tag, Naima; Korowlay, Nisaar A.ENGLISH ABSTRACT: Background: The detection of bone infection can be very difficult especially in bone with altered structure due to prior trauma or surgical procedures. Complicated osteomyelitis (COM) is becoming a public health problem especially with the difficult choice between, high cost surgery and prolonged courses of intravenous or oral antibiotic therapy, as well as the social and psychological effect of longterm disease and disability of the patient. The correct localisation of especially bone infection is still a challenge for the clinician. The single photon emission computed tomography/low dose computed tomography (SPECT/CT), by fusing the functional information with the anatomical parts, is a wellestablished tool used in many nuclear medicine studies. This improves the overall quality of the study with more clear answers. The aim of the study was to determine the added value of SPECT/CT in the management of complicated osteomyelitis (COM) in patients with endo-prosthesis, post traumatic osteomyelitis with and without metal implants and diabetic foot. Methods: This was a prospective study, between February 2010 and February 2012. Patients with suspected COM who fulfilled the selection and inclusion criteria were included. All had abnormal three phase bone scan followed by infection imaging with 99mTc labelled white blood cells and 99mTc -colloid if the99mTc labelled white blood cell study was abnormal. 67Ga citrate was used in vertebral involvement. Planar and SPECT/CT images were reviewed for presence of abnormal uptake and for its localization in bone and soft tissue. Scan results were defined as positive or negative. Both planar and SPECT/CT images were compared regarding diagnosis and precise localization of infection. The final diagnosis was obtained from surgical specimen or microbiological culture as well as clinical follow-up of all patients. Results: There were 72 patients, 29 male and 43 female with mean age of 57 yrs [range 27-88].There were 24 patients with prosthesis, 16 with hip prosthesis (PH=16), and 8 with knee prosthesis (PK=8). There were 44 patients with post traumatic osteomyelitis, 26 with metal implants (TOM=26) and 18 without metal implants (TOWM= 18). Four patients had diabetic foot (DF= 4). Infection was diagnosed in 19/72 patients on planar images and in 21/72 on SPECT/CT. Infection was diagnosed in 4 patients with prosthesis, 16 patients with post traumatic injury and one diabetic foot patient. The four patients with prosthesis, SPECT /CT added diagnostic value by excluding osteomyelitis in 3 patients and by defining the exact extent and localizing soft tissue and bone infection (STI/OM) in one patient. In 16 patients with post traumatic OM on planar images, SPECT /CT added diagnostic value, by excluding OM in 4 patients and confirming only STI, better localisation of the uptake in bone and soft tissue in 5 patients, of them 2 patient was negative on planar, and in 7 patients, confirmed and defined the exact extent of both OM and STI. One diabetic foot was positive for STI on the planar, the SPECT/CT added diagnostic value by defining the extent of the infection. In summary the added value of SPECT/CT was: a. Overall infection: 1. Exclusion of osteomyelitis by confirming only soft tissue involvement: 7 patients (10%) 2. Better localization in bone and soft tissue: 6 patients (8%) 3. Better delineation of extent of infection: 9 patients (12%) 4. None: 50 patients (70%) b. In positive cases only: 1. Exclusion of osteomyelitis by confirming only soft tissue involvement: 7 patients (33%) 2. Better localization in bone and soft tissue: 5 patients (24%) 3. Better delineation of extent of infection: 9 patients (43%) 4. None: 0 patients The overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy for infection, on planar was 90%, 100%, 100%, 97%, 97%, respectively and for SPECT/CT 100%, 100%, 100%, 100%, 100%. For OM on planar, the sensitivity, specificity , positive predictive value, negative predictive value and accuracy was 100%, 89%, 53%, 100%, 90%, respectively and for SPECT/CT 100%, 100%, 100%, 100%, 100%. Conclusion: In complicated osteomyelitis, SPECT/CT is useful in localizing, defining the exact extent of infection where the planar images are abnormal, with no added value if the planar images are negative. We recommend in clinical practice the routine use of hybrid SPECT/CT imaging in complicated osteomyelitis when planar images are abnormal.
- ItemThe added value of SPECT/CT in the evaluation of equivocal skeletal lesions in patients with known malignant disease(Stellenbosch : University of Stellenbosch, 2010-03) Ndlovu, Xolani; Warwick, James M.; University of Stellenbosch. Faculty of Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH SUMMARY: Introduction: Bone scintigraphy is used extensively in evaluating metastatic disease. There are currently no clear recommendations for the use of SPECT/CT in metastatic bone disease. Existing procedural guidelines from the Society of Nuclear Medicine (SNM) for SPECT/CT do not provide specific indications for use of SPECT/CT in bone scintigraphy, and there are currently no other guidelines for the use of SPECT/CT in bone scintigraphy that the author is aware of. The aim of this study was to investigate the additional value of SPECT/CT, and to identify the clinical indications for which SPECT/CT is most useful in patients with suspected bone metastases. Subjects and Methods: Forty-two patients with equivocal lesions on planar scintigraphy were prospectively recruited and planar imaging, SPECT, and SPECT/CT done on all patients. On reading of SPECT and then SPECT/CT, patients and individual lesions were classified as malignant, benign or equivocal. Radiological studies and available clinical information were also used during reading of scans. Review of clinical information, radiological studies and/or follow-up bone scans were used as gold standard. The results of the SPECT and SPECT/CT were compared in terms of proportion of equivocal findings and accuracy. Results: Forty-two patients with 189 skeletal lesions were examined. There was a diverse variety of primary tumours, although the majority had breast (n=22) or prostate cancer (n=8). Overall, SPECT/CT resulted in a significant reduction in the proportion of equivocal findings on both a patient-wise (p=0.0015) and lesion-wise basis (p<0.0001). The overall accuracy of SPECT/CT was significantly higher than that of SPECT on both a patient-wise (p=0.0026) and lesion-wise basis (p<0.0001). Generally SPECT/CT decreased the proportion of equivocal findings and increased the accuracy independent of the presence of bone pain, type of primary tumour, or skeletal region involved. SPECT/CT did not significantly improve the diagnostic confidence of readers in equivocal lumbar lesions although accuracy was significantly improved in this region. Conclusion: SPECT/CT performs significantly better than SPECT alone for the interpretation of equivocal planar lesions. There is no evidence that the benefit of SPECT/CT is dependent on the type of primary tumour or the presence of bone pain. Where resources are limited, SPECT/CT is indicated only in those patients in whom correct classification of the lesions in question is expected to alter the patient’s management. SPECT/CT images should be interpreted with the aid of a diagnostic radiologist or nuclear medicine physicians should acquire sufficient experience in Computed Tomographic image interpretation in order to optimise diagnostic benefit from SPECT/CT.
- ItemBrain SPECT in patients with neuropsychiatric SLE : the additional value of semi-quantitative analysis(Stellenbosch : University Stellenbosch, 2009-12) Khider, Mohamed Abdelrahman; Warwick, James; Whitelaw, Dave; University of Stellenbosch. Faculty of Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH ABSTRACT: Introduction: There is conflicting data on the value of single photon emission tomography (SPECT) for the diagnosis of neuropsychiatric SLE (NPSLE). Visual assessment of brain SPECT scans is the standard approach in clinical practice. However the definition and identification of significant changes may be limited by a high interobserver variability, especially in centres with limited experience. This may be reduced by a more objective semi-quantitative assessment. The objectives of this study were to determine the sensitivity and specificity of SPECT for the detection of NPSLE at our institution using visual assesment, to determine the additional value of using an objective semi-quantitative diagnostic criterion, and to investigate the correlation between abnormal perfusion pattern and clinical NPSLE classification in patients with active NPSLE. Material and methods: Nineteen patients with NPSLE and 19 normal controls were studied with brain SPECT. Scans were interpreted blindly by two nuclear medicine physicians using two methods; visual and semi-quantitative assessments. In the visual method, overall visual impression was recorded for each scan using a four point scale, where A=normal, B=probably normal, C=probably abnormal, and D=abnormal. In addition, each brain region was assigned a severity score from 0=normal perfusion to 3=severe hypoperfusion. In the semi-quantitative assessment, ten-band color scale was used, and perfusion deficit was quantified on the side with the lower color intensity comparing to the contralateral side. A score was given to the region with perfusion deficit according to the difference (in color bands) between the two hemispheres. Analysis was performed for the visual assessment method (overall impression and severity scores) and the semi-quantitative assessment method using a receiver operator characteristic (ROC) curve. Optimal cut-off points were determined and the accuracy of the different techniques was also compared statistically. Finally, the correlation was determined between the SPECT perfusion pattern and the clinical pattern of disease. Results: An ROC curve analysis for the overall visual impression resulted in an area under the curve of 0.76. At a cut-off point of C (probably abnormal), brain SPECT had 89% sensitivity and 57% specificity for the diagnosis of NPSLE. The severity score which include the total severity score and the modified total severity score resulted in areas under the curve of 0.75 and 0.79 respectively. The semi-quantitative assessment resulted in areas under the ROC curve of 0.80. Statistically, there was no difference between the overall visual impression, visual severity scores, and the semi-quantitative assessment. Agreement analysis between the SPECT pattern and clinical pattern of disease showed agreement in 91.6% in the diffuse pattern, whereas agreement in the focal pattern was seen in only 42.8%. Discussion and Conclusion: In this study, we found that brain SPECT is able to diagnose active NPSLE with a high sensitivity and moderate specificity. The overall visual impression, visual severity scores, and the semi-quantitative assessment showed no significant differences between the techniques. The use of the semi-quantitative assessment described may be useful in centers with limited experience in the interpretation of brain SPECT. The correlation between the SPECT pattern and clinical disease pattern may provide some insights into the pathophysiology of NPSLE.
- ItemThe effect of reconstruction algorithms (iterative versus filtered backprojection) on the diagnosis of single pulmonary nodules using Thallium-201 and Technetium-99m MIBI SPECT(Stellenbosch : Stellenbosch University, 2004-04) Ambayi, Rudo; Ghoorun, S.; Dupont, P.; Stellenbosch University. Faculty of Medicine and Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH ABSTRACT: This study involved 33 patients, 19 men and 14 women. The age range was wide (20-90 years) and median age was 57 years. These patients had a single pulmonary nodule (SPN) defined radiologically as a well defined, round or oval intrapulmonary lung lesion not associated with atelectasis or adenopathy on chest radiography or computed tomography. Patients were investigated with Tc-99m MIBI and TI-201 (25 patients) and with Tc-99m MIBI alone (8 patients). Single photon emission computed tomography images were reconstructed using both iterative reconstruction (Ordered Subsets - Expectation Maximisation: aSEM) and filtered backprojection (FBP), on the Hermes system. Transverse, coronal and sagittal slices were displayed on the screen using a grey scale. The aSEM and FBP images for each study were co-registered semi-automatically using the multimodality programme on the Hermes. The best slice for the lesion was chosen according to the best view used to locate the SPN on chest radiograph. Regions of interest (Ral) were drawn manually outside the outer margin of the detected lesion, first on the aSEM image. This was automatically mirrored on the co-registered FBP image. For most patients, the background was automatically mirrored horizontally on the contralateral side, again, first on the OSEM then automatically on the FBP image. Automatic vertical mirroring or manual horizontal mirroring was used when background was found to be in a visually 'hot' area like the heart or vertebrae. The average counts and standard deviation of the Ral and background were generated automatically. Semi-quantitative image analysis was done by calculating the signal-to-noise ratio (SNR) and tumour-to-background (TIB) ratio using the following formulae: SNR = Mean counts ROI(lesion) - Mean counts background Standard deviation background TIB rati.o = -M---e-a-n-'--c-o--u-n-'t-s- ROI(lesion) Mean counts background Detection was found to be the same for the two reconstruction algorithms, that is, every lesion detected by using OSEM could also be detected by using FBP. However lesion detection did differ between Tl-201 and Tc-99m-MIBI. Sensitivity and specificity were calculated for different thresholds of SNR and TIB ratios. Receiver operating characteristics (ROC) curves were drawn to represent the different sensitivities and specificities at each threshold. Tuberculosis (TB) was not included in this analysis as uptake of Tl-20l was found to be significantly high and comparable to that of malignant nodules. However the effect of OSEM and FBP on the 'positive' TB nodules was assessed separately. By calculating the area under the ROC curves, TI-201 using OSEM was shown to be more accurate at differentiating malignant nodules from benign ones than FBP. Although this difference was not statistically significant (p=0.1 0), there was a clear tendency. The two reconstruction algorithms were found to be almost equally accurate, when using Tc-99m-MIBI, the difference between them being considerably insignificant. In conclusion, it was shown that there is a tendency that OSEM outperforms FBP for studies using Tl-201 but not for Tc-99m-MIBI.
- ItemImaging of renal hyperparathyroidism using SPECT/CT with low-dose localizing CT(Stellenbosch : Stellenbosch University, 2013-12) Doruyter, Alexander Govert George; Warwick, James Matthew; Stellenbosch University. Faculty of Medicine and Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Division of Nuclear Medicine.ENGLISH ABSTRACT: Background: Hybrid imaging using single photon emission computed tomography/low dose (x-ray) computed tomography (SPECT/LDCT) is of benefit in preoperative scintigraphy of primary hyperparathyroidism. The role of SPECT/LDCT in preoperative assessment of renal hyperparathyroidism has not yet been examined. The aim of the study was to determine whether SPECT/LDCT conferred any benefit over SPECT alone in terms of detection and/or localization of hyperfunctioning parathyroid tissue in this patient group. Methods: A retrospective study of patients with renal hyperparathyroidism and positive planar and SPECT scintigraphy was undertaken. All patients underwent planar scintigraphy using 99mTc-pertechnetate immediately followed by 99mTc-sestamibi as well as SPECT/LDCT 60 min after sestamibi injection and a delayed static image to assess for differential washout at 2-3 hours. Planar subtraction images were generated. For each patient, two nuclear physicians reported on planar+ SPECT images followed by planar + SPECT/LDCT images (assisted by a radiologist). Confidence for the presence of hyperfunctioning parathyroid tissue as well as confidence of location was scored on a Likert-type scale. Interpretation of planar + SPECT was compared with interpretation of planar + SPECT/LDCT. The impact of LDCT on equivocal lesions and number of ectopic lesions detected was also assessed. Results: Twenty patients (M:13; F:7) imaged between February 2008 and June 2011 were included [mean age: 40 years (24 – 55)]. Mean creatinine was 687 μmol/l (169-1213), mean corrected calcium: 2.55 mmol/l (1.95-3.33) and median PTH 167 pmol/l (2.4 - >201). Thirty-five lesions were detected on planar and SPECT and this was unchanged after assessment of the LDCT data. Confidence for the presence of parathyroid pathology changed in 5 patients (5 lesions) with the addition of LDCT. LDCT changed the mean confidence of parathyroid pathology from 3.17 to 3.29 (p=0.16). Addition of LDCT reduced the number of equivocal lesions from 18 (14 patients) to 14 (10 patients) (p=0.13). The addition of LDCT changed localization in 4 lesions (3 patients). Confidence in localization of pathology changed in 9 lesions (7 patients) and the mean localization confidence score was improved from 4.2 to 4.46 (p=0.002) with LDCT. The number of lesions classified as ectopic increased from 5 (on planar+SPECT) to 8 (with addition of LDCT) (p=0.25). Conclusion: In renal hyperparathyroidism SPECT/LDCT altered localization of lesions detected on planar and SPECT alone and improved reader confidence of localization accuracy. SPECT/LDCT conferred no additional benefit over SPECT in terms of detection, confidence of parathyroid pathology or ability to distinguish equivocal from non-equivocal parathyroid lesions. The addition of LDCT did not detect significantly more ectopic lesions. Whereas the minor improvement in reader confidence of localization (with addition of LDCT) was of questionable clinical significance, we speculate that the changed and presumably improved localization of lesions on SPECT/LDCT had potential clinical impact in a significant proportion of patients. On this basis we recommend the use of hybrid SPECT/LDCT in imaging of renal hyperparathyroidism when surgery is considered.
- ItemAn investigation of the contribution of Single Photon Emission Computed Tomography to the diagnosis of skeletal metastases using bone scan in the African context(Stellenbosch : Stellenbosch University, 2003-12) Elmadani, Ahmed Elkhidir; Warwick, James M.; Stellenbosch University. Faculty of Medicine and Health Sciences. Dept. of Nuclear Medicine.ENGLISH ABSTRACT: Planar bone scintigraphy is highly sensitive but it may not be sensitive enough to detect subtle lesions in complex bony structures such as the spine. The accurate anatomic localisation of lesions in regions such as this is also limited using planar images. Single Photon Emission Computed Tomography (SPECT) results in a higher lesion contrast resulting in an improved sensitivity for the detection of subtle lesions. SPECT also enables improved lesion localisation, often valuable in distinguishing benign from malignant disease in the spine. A number of previous studies have demonstrated that the addition of SPECT of the spine significantly enhances the value of bone scintigraphy for the detection of bone metastases compared to planar imaging alone. These studies were however not done in the African context where patients typically present with more advanced disease. In a retrospective study of 576 patients with known primary tumors sent to our institution for bone scintigraphy for the diagnosis of bone metastases, we evaluated 119 patients in whom both planar imaging and SPECT were obtained. The studies were graded for the probability of metastatic disease, and the number of spinal lesions was determined with and without SPECT. The influence of adding SPECT on the interpretation of the study was determined in terms of the reported probability of metastatic disease, the exclusion and confirmation of metastatic disease, the decisiveness of interpretation, and the number of spinal lesions. The addition of SPEeT resulted in a statistically significant change in the interpretation of studies, although the actual numbers of patients affected were relatively small. SPEeT resulted in a more decisive interpretation of bone scintigraphy. There was a significant increase in the number of spinal lesions detected after the addition of SPEeT. It was concluded that although the use of SPEeT is ideal, acceptable results could be achieved using planar imaging alone in this patient population. This is particularly relevant in the African context, where SPEeT is often unavailable or scarce and in great demand.
- ItemOptimal utilization of gamma camera time in Tc-99m MDP bone scintigraphy(Stellenbosch : University of Stellenbosch, 2007-03) Jawa, Zabah Muhammad; Rubow, Sietske; Warwick, James; University of Stellenbosch. Faculty of Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.Introduction: Whole body bone scintigraphy with Tc-99m MDP is able to provide a survey of the entire skeleton. The question arises if it is mandatory to perform a whole body bone scan in all patients, irrespective of the clinical indication. The aim of this study is to determine the implications of performing limited imaging in patients who had whole body bone scan for various clinical patholgy with Tc-99m MDP, in order to determine if limited imaging would be acceptable in selected pathologies. This may enable gamma camera time to be optimally utilized in units with limited facilities. Materials and Methods: Reports of 3015 patients with various clinical pathologies who had whole body bone scans with Tc-99m MDP in our department from January 2002 to December 2004 were retrospectively reviewed. The presence of pathologic radiotracer uptake was analyzed in order to establish the pattern of distribution. Clinically significant skeletal lesions were classified according to the anatomical regions where they were located viz; skull (including the neck), axial skeleton (including the pelvis and shoulders) and limbs. Results: Our results showed that in patients with lung cancer, soft tissue sarcoma, and myeloma, there was an error in more than 25% of patients when limited imaging was performed. In patients with cancer of the breast, prostate, kidney, gastrointestinal system, and reproductive system and lymphoma there is an error in less than 5% of patients when limited imaging is employed. For iv patients with more localized musculoskeletal disorders such as suspected stress fractures, complicated joint prosthesis and avascular necrosis of the femur head, regional imaging of the area of pathology showed a percentage error of less than 6%.
- ItemPulmonary embolism diagnosis : a clinical comparison between conventional planar and SPECT V/Q imaging using Krypton 81m – with CTPA as the gold standard(Stellenbosch : University of Stellenbosch, 2010-03) Ngoya, Patrick Sitati; Korowlay, Nisaar A.; University of Stellenbosch. Faculty of Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH ABSTRACT: Single photon emission computed tomography (SPECT) with a superior contrast resolution has been shown to be more sensitive and specific with a lower nondiagnostic rate than planar imaging in many nuclear medicine studies but it is still not being routinely implemented in V/Q studies at many centres including Tygerberg Hospital. There are many studies on V/Q SPECT using Technegas as a ventilation agent but very limited studies available on 81m Kr gas. Aim: To clinically compare conventional planar and SPECT V/Q imaging using 81mKr gas in the diagnosis of pulmonary embolism, with CTPA as the gold standard. Patients and Methods: All patients referred with clinical suspicion of pulmonary embolism were assessed. The inclusion criteria were normal chest radiograph, normal renal function and no contrast allergy. Exclusion criteria were age below 18 years old, pregnancy, abnormal chest radiograph, abnormal serum creatinine/urea levels and unstable patients. A Well’s score was assigned to each enrolled patient. Perfusion scintigraphy was performed after intravenous injection 125 MBq of 99mTc MAA. Ventilation scintigraphy was performed with 81mKr gas. On a dual head camera, SPECT was done before planar acquisition, while perfusion was done before ventilation imaging in the same position. Planar V/Q images consisted of 6 standard views. All V/Q SPECT images were reconstructed using ordered-subset expectation-maximization (OSEM) algorithm and a post-reconstruction 3D Butterworth filters were applied. V/Q Planar and V/Q SPECT images were later evaluated and reviewed separately and reported based on recent EANM guidelines blinded to the CTPA results. All patients underwent multi-slice CTPA examinations on a 40-detector row scanner. The images were later assessed and reported blinded to the V/Q results. Statistical analysis was done using the Fisher exact test for comparison of categorical variables and the one-way ANOVA for continuous variables (p<0.05 was significant). Results: A total of 104 consecutive patients were referred with clinical suspicion of pulmonary embolism. Seventy-nine patients were excluded from this study mostly due to abnormal serum creatinine/urea levels. Only 25 patients were included in this study, with a mean age of 48 ± 19 years, and 64% being females. When compared to CTPA as gold standard, the prevalence of PE was 16% [5% – 37% at 95% CI], sensitivity 75% [21% – 99% at 95% CI], specificity 90% [68% – 98% at 95% CI], positive predictive value 60% [17% – 93% at 95% CI], negative predictive value 95% [73% – 100% at 95% CI] and diagnostic accuracy 88% [69% – 97%at 95% CI] for both V/Q Planar and SPECT. V/Q Planar showed a lower reader confidence i.e. could only clearly resolve 72% of cases compared to V/Q SPECT, which could precisely interpret all cases, showed more and better delineated mismatch vs match and segmental vs non-segmental defects. All patients who were scored as PE unlikely on Wells’ score (4) had PE ruled out on CTPA (p=0.04581) as well as 89% of patients on V/Q SPECT and V/Q Planar. Conclusion: Based on this study, V/Q Planar and V/Q SPECT have a similar diagnostic performance in patients with a normal or near normal chest X-rays.
- ItemResponse to radioiodine in male hyperthyroid patients at Tygerberg Hospital(Stellenbosch : University of Stellenbosch, 2009-03) Onimode, Yetunde Ajoke; Ellmann, Annare; Korowlay, Nisaar; University of Stellenbosch. Faculty of Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH ABSTRACT: Radioiodine therapy is reputed to yield poorer results in male patients than in females. We retrospectively reviewed the records of 308 patients treated with radioiodine-131 (RAI) for Graves’ disease (n=266, 86.4%), toxic multinodular goitres (n=35, 11.4%) and toxic solitary nodules (n=7, 2.3%). The mean age of the men was 44 ±13.6 years (range 14-77 years). Patients with GD were predominantly in the younger age groups, while those with toxic nodular goitres were in the older range. Two hundred and fifty-nine patients (84.1%) were treated with a single dose of RAI, while 49 (15.9%) required further doses. A second dose had to be administered to 38 patients, while 8 received 3 doses, 2 got 4 doses and 1 patient had 5 doses in all (these included a first dose received prior to referral to our Thyroid Clinic). Cure was determined as euthyroidism or hypothyroidism at the 3-month follow-up visit. The average pre-treatment T4 value was 68.9 ± 31.8 pmol/L (range 5.7 – 155 pmol/L); while the mean Tc-99m pertechnetate uptake value was 15.8 ± 10.9% (range 0.88 - 62.9). Patients with GD presented with more severe hyperthyroidism than the other patients; mean free T4 of 71.9 ± 31.1 pmol/L compared to 51.4 ± 29.9 pmol/L for the TMG group of patients, and 39.6 ± 26.8 pmol/L for the TSN group (ANOVA p<0.0001, confirmed by the Kruskal-Wallis test). Patients with TMG and TSN were treated with higher doses than patients with GD; mean first doses of 349.3 ± 88.5 MBq and 428.1 ± 28.6 MBq respectively, compared to a mean dose of 325.1 ± 69.3 MBq for patients with GD. Treatment with multiple doses of RAI correlated with higher values of T4 and T3 at presentation (p<0.0001). However, none of the baseline variables of age, T4 and T3, and first dose of RAI was significant predictors of free T4 outcome at 3 months. A consistently higher dose was administered to the male patients, compared to female patients of similar age, diagnosis and level of thyrotoxicosis (Tc-99m pertechnetate uptake). Despite this, male patients had similar outcomes as the female patients 3 months after therapy. Our findings lend weight to the theory that male patients are more difficult to treat than their female counterparts, seeing that the former had similar outcomes despite the significantly higher doses of RAI administered to the males.
- ItemWorking towards the implementaion of an international accreditation programme in a Nuclear Medicine Department of a South African teaching hospital(Stellenbosch : Stellenbosch University, 2005-04) Eiselen, Thea; Ellmann, Annare; Stellenbosch University. Faculty of Medicine and Health Sciences. Dept. of Medical Imaging and Clinical Oncology. Nuclear Medicine.ENGLISH ABSTRACT: Introduction: Quality assurance in Nuclear Medicine is of utmost importance in order to ensure optimal scintigraphic results and correct patient management. A customised Quality Management System (QMS) should be documented and implemented by following the international guidelines set by the International Standardisation Organization (ISO). Materials & Methods: A Quality Control Manual (QCM), defining the departmental quality policy, mission, vision and objectives was customised following the framework of a tried and tested design. As ISO focuses on client satisfaction and staff harmony, the following departmental objectives were audited in working towards the accreditation of the Nuclear Medicine Department of Tygerberg Hospital: referring physician satisfaction, patient satisfaction as well as staff satisfaction and harmony. Information was collected by means of questionnaires completed by referring physicians and staff members. One-on-one interviews were executed on patients. An international ISO accredited Nuclear Medicine department was visited to establish the suggested path to follow en route to successful ISO accreditation and certification. Results: Referring physicians indicated overall satisfaction with service provision, but a need for electronic report and image transfers seemed too dominant. The patient satisfaction survey resulted into overall satisfaction with personal service providing, but the provision of written and understandable information, long waiting times and t equipment must receive attention. Staff questionnaires indicated a general lack of communication between different professional groups and the need for interpersonal loyalty and team building. Improvement measures were identified to ensure the continuous improvement of the QMS by focusing on these quality parameters. Conclusion: The department has QA procedures in place, but does not meet all criteria for external accreditation. In order to ensure departmental harmony and sustainability of client and staff satisfaction, the departmental objectives in measured and improved where needed. The successful implementation and continuous improvement of a customised QMS, following the guidelines outlined in the QCM will lead to successful accreditation.