Browsing by Author "Le Roux, S. G."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemMicroCT-based bulk density measurement method for soils(South African Institution of Civil Engineering, 2019) Le Roux, S. G.; Du Plessis, A.; Clarke, C. E.High-resolution micro-computed tomography (microCT) is a method growing rapidly in popularity and has been applied to various soil studies with great success, especially for 3D characterisation of pore spaces or mineral distributions. However, microCT is not typically used for soil bulk density measurements, probably due to relatively simple and fast alternatives. Besides the complex process of image analysis from microCT scans, the method is also limited in resolution, which can result in incorrect total porosity estimation. This is especially true for granular materials, such as soils with small pore spaces between particles. In this work we demonstrate a different, yet very simple methodology for microCT adapted to overcome these limitations by using only volumetric measurements of the samples, and not segmentation of pore spaces or density calibrations. This method allows accurate bulk density determination for soil clods and cores. The method is faster than tradition methods, and it allows for additional analyses, such as surface area, macro-porosity, connected pore network and macro-particle shape analysis. The method is tested and directly compared for the same samples to the traditional waxing Archimedes method, with good correlation. The microCT scans of waxed samples also indicate sources of possible error in the waxing Archimedes method by visualising trapped air and wax penetration into open pore spaces. The method is then applied to cores and local bulk density measurements, and their variability down the cores is demonstrated, which can be very useful in complex soil profiles. The method is robust in varying resolution and image blur as it makes use only of volumetric measurements of the entire sample, not image grey-value calibration or segmentation of pore spaces.
- ItemA pilot study investigating the presence of voids in bulk fill flowable composites(South African Dental Association, 2017) Mulder, R.; Mohammed, N.; Du Plessis, A.; Le Roux, S. G.OBJECTIVE: To investigate the presence of voids in bulk fill flowable composites. METHODS: This study investigated two well-known bulk-fill flowable composites, Smart Dentin Replacement (SDR) (Dentsply/Caulk, Milford, Germany) and Filtek bulk fill flowable (FBF) (3M ESPE, Minnesota, USA). Three ampules of each material were randomly selected. The ampules were subjected to 3D Micro-CT (General Electric Phoenix V|Tome|X L240) reconstruction in order to assess the presence of any voids within the ampules. RESULTS: Voids were present in all the ampules. The total void percentage for each group of three ampules was found to be SDR : 1.147 % and FBF : 0.0424 %. There was a significant difference between the volume of voids for SDR and FBF, p-value=0.003924. CONCLUSION: Voids were found in the randomly selected samples of bulk-fill flowable composites. This is undesirable and manufacturers should be urged to ensure that no voids are present, or at least are minimized in the ampules of material.