Browsing by Author "Binder, Anke"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemAbrogation of glucocorticoid receptor dimerization correlates with dissociated glucocorticoid behavior of compound A(HighWire Press, 2010-03) Robertson, Steven; Allie-Reid, Fatima; Vanden Berghe, Wim; Visser, Koch; Binder, Anke; Africander, Donita; Vismer, Michael; De Bosscher, Karolien; Hapgood, Janet; Haegeman, Guy; Louw, Ann; A-7620-2012Compound A (CpdA), a dissociated glucocorticoid receptor modulator, decreases corticosteroid-binding globulin (CBG), adrenocorticotropic hormone (ACTH), and luteneinizing hormone levels in rats. Whether this is due to transcriptional regulation by CpdA is not known. Using promoter reporter assays we show that CpdA, like dexamethasone (Dex), directly transrepresses these genes. Results using a rat Cbg proximal-promoter reporter construct in BWTG3 and HepG2 cell lines support a glucocorticoid receptor (GR)-dependent transrepression mechanism for CpdA. However, CpdA, unlike Dex, does not result in transactivation via glucocorticoid-responsive elements within a promoter reporter construct even when GR is co-transfected. The inability of CpdA to result in transactivation via glucocorticoid- responsive elements is confirmed on the endogenous tyrosine aminotransferase gene, whereas transrepression ability is confirmed on the endogenous CBG gene. Consistent with a role for CpdA in modulating GR activity, whole cell binding assays revealed that CpdA binds reversibly to the GR, but with lower affinity than Dex, and influences association of [3H]Dex, but has no effect on dissociation. In addition, like Dex, CpdA causes nuclear translocation of the GR, albeit to a lesser degree. Several lines of evidence, including fluorescence resonance energy transfer, co-immunoprecipitation, and nuclear immunofluorescence studies of nuclear localization- deficient GR show that CpdA, unlike Dex, does not elicit ligand-induced GR dimerization. Comparison of the behavior of CpdA in the presence of wild type GR to that of Dex with a dimerization-deficient GR mutant (GRdim) strongly supports the conclusion that loss of dimerization is responsible for the dissociated behavior of CpdA.
- ItemComparison of quantitative techniques including Xpert MTB/RIF to evaluate mycobacterial burden(PLOS, 2011-12) Van Zyl-Smit, Richard N.; Binder, Anke; Meldau, Richard; Mishra, H.; Semple, P. L.; Theron, G.; Peter, J.; Whitelaw, A.; Sharma, S. K.; Warren, Rob; Bateman, E. D.; Dheda, K.Introduction: Accurate quantification of mycobacterial load is important for the evaluation of patient infectiousness, disease severity and monitoring treatment response in human and in-vitro laboratory models of disease. We hypothesized that newer techniques would perform as well as solid media culture to quantify mycobacterial burden in laboratory specimens. Methods: We compared the turn-around-time, detection-threshold, dynamic range, reproducibility, relative discriminative ability, of 4 mycobacterial load determination techniques: automated liquid culture (BACTEC-MGIT-960), [3H]-uracil incorporation assays, luciferase-reporter construct bioluminescence, and quantitative PCR(Xpert -MTB/RIF) using serial dilutions of Mycobacterium bovis and Mycobacterium tuberculosis H37RV. Mycobacterial colony-forming-units(CFU) using 7H10-Middlebrook solid media served as the reference standard. Results: All 4 assays correlated well with the reference standard, however, bioluminescence and uracil assays had a detection threshold $16103 organisms. By contrast, BACTEC-MGIT-960 liquid culture, although only providing results in days, was user-friendly, had the lowest detection threshold (,10 organisms), the greatest discriminative ability (1 vs. 10 organisms; p = 0.02), and the best reproducibility (coefficient of variance of 2% vs. 38% compared to uracil incorporation; p = 0.02). Xpert-MTB/RIF correlated well with mycobacterial load, had a rapid turn-around-time (,2 hours), was user friendly, but had a detection limit of ,100 organisms. Conclusions: Choosing a technique to quantify mycobacterial burden for laboratory or clinical research depends on availability of resources and the question being addressed. Automated liquid culture has good discriminative ability and low detection threshold but results are only obtained in days. Xpert MTB/RIF provides rapid quantification of mycobacterial burden, but has a poorer discrimination and detection threshold.