Department of Mechanical and Mechatronic Engineering
Permanent URI for this community
Browse
Browsing Department of Mechanical and Mechatronic Engineering by Author "Angula, Ester"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemNumerical performance evaluation of a delugeable flat bare tube air-cooled steam condenser bundle(Stellenbosch : Stellenbosch University, 2015-03) Angula, Ester; Reuter, H. C. R.; Stellenbosch University. Faculty of Engineering. Dept of Mechanical and Mechatronic Engineering.ENGLISH ABSTRACT: In this study, one and two-dimensional models are developed for the evaluation of the thermal performance of a delugeable flat tube bundle to be incorporated in the second stage of an induced draft hybrid (dry/wet) dephlegmator (HDWD) of a direct air-cooled steam condenser (ACSC). Both models are presented by a set of differential equations. The one-dimensional model is analysed analytically by using three methods of analysis which are: Poppe, Merkel, and heat and mass transfer analogy. The two-dimensional model is analysed numerically by means of heat and mass transfer analogy method of analysis whereby, the governing differential equations are discretised into algebraic equations using linear upwind differencing scheme. The two-dimensional model’s accuracy is verified through a comparison of the two dimensional solutions to one dimensional solutions. Satisfactory correlation between the one and two-dimensional results is reached. However, there is a slight discrepancy in the solutions, which is mainly due to the assumptions made in one-dimensional model. The effect of tube height, tube pitch, tube width, deluge water mass flow rate, frontal air velocity, steam, and air operating conditions on the heat transfer rate and air-side pressure drop for both wet and dry operating modes are investigated. The long tube height, large tube width, small tube pitch, and high frontal air velocity are found to increase the tube bundle’s performance. However, this performance is associated with a high airside pressure drop. The performance of the deluged flat tube bundle is found to be less sensitive to the changes in the deluge water mass flow rate and air operating conditions. Furthermore, the best configuration of a delugeable flat tube bundle is identified through a comparison to round tube bundle presented by Anderson (2014). The performance of the round tube bundle is found to be around 2 times, and 1.5 times of that of flat tube bundle, when both bundles operate as an evaporative and dry air-cooled condenser respectively.